CE/EMC Certified, High Efficiency Full Power 20000 Peak Power 10000W Off Grid Pure Sine Wave Solar Power Inverters Converters DC TO AC Voltage Transformer LED Display Iron Shell
- As the core components, transfer the DC power to AC power, we use the high frequency transformer, ensure the stable and full AC output with no failure.
- Adapted the imported capacitor, large electricity, better performance, longer lifetime, safer usage.
- High quality true copper inductance, filter the wave form, ensure the true pure sine wave AC output, safeguard your equipment.
- No electromagnetic interference to your equipment, such as no noise for TV, FM radio, Audio.
- With the big radiating flange, better cooling performance, ensure the best inverter working condition.
- All big mosfet, larger load capacity, stable the inverter performance, supply the continuous AC output.
- Earth connection for both PCB board and output, more safe for the load and the usage.
- The PCB thickness of 2.00mm, thicker than the most inverters on the market, allow the stronger current floating on the circuit, increase the load capacity.


DC Voltage
|
12V or 24V or 36V or 48V or 72V or 110V
|
Voltage Range
|
10-15VDC or 21-30VDC or 42-60VDC or 100-120VDC
|
NO Load Current Draw
|
<1A
|
Efficiency
|
>90%
|
DC Connector
|
Cables With Clips or Car Adaptor
|
AC Voltage
|
100/110/120VAC or 220/230/240VAC
|
Continuous Power
|
10000W
|
Surge Power
|
20000W
|
Waveform
|
Pure Sine Wave
|
Frequency
|
50HZ or 60HZ
|
AC Regulation
|
3%
|
Low Voltage Alarm
|
10DC±0.5V or 20.5DC±1V or 44VDC±1V or 100VDC±1V
|
Low Voltage Shut Down
|
9.5DC±0.5V or 19.5DC±1V or 42VDC±1V or 96VDC±5V
|
Over Load
|
Shut Off Output
|
Over Voltage Shut Down
|
15.5V or 30.5V or 61.2V or 120V
|
Over Thermal
|
Shut Off Output Automatically
|
Fuses
|
Short Circuit
|
Working Temperature
|
Between -10centi and +50centi
|
Working Humidity
|
20%~90%RH non-condensing
|
Storage Temperature
|
Between -30centi and +70centi
|
Start
|
Soft Start
|
Cooling Ways
|
Cooling Fan
|
Total Harmonic Distortion THD
|
<5%
|
Machine Size(mm)
|
600*280*160 |
Packing Size(mm)
|
645*515*240 |
Net Weight(kgs)
|
16KG
|
Gross Weight(kgs)
|
19KG
|
Packing Type
|
Carton Packing
|

-
Pure Sine Wave, as good as the grid power
-
Full Power
-
Core Technology, German Design
-
Most Advanced Program in Software
-
Complete Protection Non Defect Rate,
-
Better EMC – Electro Magnetic Compatibility,
-
No Noise for TV or Stereo Sound
-
SMT- Surface Mounting Technology
-
All Big Imported Mosfet,Strong Driving Capacity
-
PCB Thickness :2.00m
-
LED Display
-
Compact Design, Less Weight, Full Power,
-
Single Layer Design, Easy to Repair if any.
-
Earth Connection for Both Inverter and PCB,
-
Low No Load Current Draw
-
Durable quality with 10 years usage,
-
Alarm and LED Indication Light for error warning. New inevrter with LED display, let you monitor the inverter input voltage and output voltage in time. With this function, you will know about the inverter condition more clearly.
-
Sufficient Heat Radiation
-
More Vent Holes on the plates and the bottom for heat radiation
-
Popular Metal Black Design
-
Big Current Connector,
-
All kinds of socket are available
-
Strong Wiring Row on AC End,
-
Best quality ever in the market
-
Factory Price.
-
For 12V inverter, there are two input positive connectors and two input negative connectors. For other inverter (24V, 36V,48V, 60V, 72V, 96V, 110V), there is input positive connector and input negative connector.







- When the load is short circuit, the inverter will stop working.
- When the use environment is stuffy, the heat of the inverter can not be radiated. The temperature is above the rated temperature, the inverter will stop working.
- The battery voltage is above the rated voltage of the inverter, the inverter will stop working.
- The battery’s voltage falls during the usage. When it is lower than the rated voltage, the inverter will automatically cut the input voltage for the self protection.
- It can avoid the DC high voltage’s surging attack upon the electronic components inside.
- When the appliances’ power is higher than the inverter’s power, the inverter will stop working for self protection.
- When the appliances’ current is bigger than the inverter’ current, the protection components on the board will be cut automatically for self protection.
- When the appliance’s resistance is bigger than inverter’s, the fuses on the socket will be automatically cut off for self protection.
- It can avoid the accidents of burning the inverter if the positive and the negative poles are reverse connected.
For resistive load applications:
- If you need the inverter to run the resistive load (like laptop, TV, electric cooker, LED light), please choose the inverter with continuous power higher than the appliance’s rated power.
- For example, for the power inverter with continuous power 2500w,it is suggested to run the appliance with rated power less than 2500w. It is best to use 80% of the rated power.
- If you need the inverter to run the inductive load (for appliance such as compressor, motor, water pump), please calculate the power of inverter 3 to 7 times higher than the rated power of your appliance.


- For the small capacity, The inverter will be sent by DHL, EMS, Fedex and e-EMS, it will take 3-12 days for shipping.